-6%
, , , ,

6ES7241 6ES7 241-1CH30-1XB0 CB1241 RS485 Communication Board

Availability:

Out of stock


7,070.00৳ 10,754.00৳ 

1CH30 20Y95NNP1CH30 21Y95NNP1CH30 95NNPCB1241 New OpenedCB12411CH30Board New
Clear
Compare

6ES7241-1CH30-1XB0

SIMATIC S7-1200, Communication Board CB 1241, RS485, terminal block, supports Freeport

Overview

* For fast, high-performance serial data exchange via point-to-point connection
* Implemented protocols: ASCII, USS drive protocol, Modbus RTU
* Additional protocols can be loaded later
* Simple parameterization with STEP 7 Basic
* Can be plugged directly into the CPU

Application

The CB 1241 communication board RS 485 is used for fast, high-performance
serial data exchange via point-to-point connections.

Point-to-point coupling is possible, for example, to:

* SIMATIC S7 automation systems and systems of many other manufacturers
* Printers
* Robot controls
* Modems
* Scanners
* Bar code readers, etc.

The CB 1241 communication board RS 485 can be plugged directly into all
SIMATIC S7-1200 CPUs.

This provides users with the following advantages:

* Optimal adaptation:
With communication boards, users can optimally adapt their controllers even to
more complex tasks.

* Flexibility:
If the task is expanded subsequently, the controller can be upgraded. Updating
of the user program is extremely simple.

* Use where space is limited:
The communication boards are directly plugged into the CPU, enabling the
controller to be expanded without taking up any additional space.

Design

The communication boards are plugged straight into the holder on the front of
the S7-1200 CPU.

* Installation:
Communication boards are plugged directly into the SIMATIC S7-1200 CPU and are
thus connected electrically and mechanically with the CPU.

* The installation dimensions of the CPU remain unchanged.
* Replacement of all communication boards is facilitated by removable terminals (“permanent wiring”).

Function

On the Communication Board CB 1241 RS 485, the following standard protocols
are available:

* ASCII:
For interfacing to third-party systems with simple transmission protocols,
e.g. protocols with start and end characters or with block check characters.
The interface handshake signals can be queried and controlled via the user
program.

* Modbus:
For communication according to the Modbus protocol with RTU format:

* Modbus Master:
Master-slave interfacing with SIMATIC S7 as master.

* Modbus slave:
Master-slave interfacing with SIMATIC S7 as slave; message frame traffic from
slave to slave not possible.

* USS drive protocol:
Instructions for connection of USS protocol drives are specifically supported.
In this case, drives exchange data over RS485. It is then possible to control
these drives, and to read and write parameters.

Additional drivers can also be downloaded.

##### Parameterization

The parameterization of the Communication Board CB 1241 is particularly user-
friendly and simple with STEP 7 Basic:

The user specifies the properties of the module by means of a parameterization
environment integrated into STEP 7 Basic.

 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

There are no reviews yet.

Select at least 2 products
to compare